We share your goal: get the job done most efficiently

 

We provide you with a power solution, whether as standby during an emergency outage or for continuous power in case of power cut. The Olympian product range offers a cost-effective package to meet the changing power needs of various sectors, whilst also being suitable for use in domestic applications.

 

Over 700 Olympian generator sets are used around the island, from the hotels industry to the telecommunications sector. We provide a wide choice of generators and you can rely on Scomat for exceptional service and product support.

 

 

What's in for you?


  • Range from 10 to 550 kVA.
  • Powered by a Perkins diesel engine.
  • Ready to use and competitive prices.
  • Highly reliable with high horse power and low emissions.
  • Can be configured with various options to suit your specific needs
  • A wide range of spare parts available in our shop

 

 

All generator sets are manufactured for optimum performance at an ISO9001 certified Caterpillar facility, factory tested to design specifications at full load conditions, fully engineered with a range of options and accessories and backed by excellent service and support.

 


Features:

Engine

  • Industrial water cooled PERKINS diesel engine
  • Electrical system, 12 VDC

Alternator

  • Self excited brusless generator
  • Insulation system, class H
  • Drip proof alternator air intake (IP23)
  • Class H with tropicalisation and antiabrasion
  • Electrical design in accordance with BS5000 Part 99, IEC60034-1, VDE0530, UTE51100

Control System

  • Digital metering and monitoring of genset with LCD display, giving all diagnostic information and alarms.

Exhaust System

  • Heavy Duty industrial capacity exhaust silencer (approximately 10 dB reduction)

Cooling System

  • Standard ambient temperatures up to 50° C (122° F)
  • Fan, fan drive and charging alternator fully guarded
  • Antifreeze protection coolant

Circuit Breaker

  • 3-pole miniature circuit breaker (mcb) mounted on vibration isolated cabinet

Automatic Voltage Regulator

  • Voltage regulation ±1.0 %
  • Provides fast recovery from transient load charges

 

  

 

Options:

 

  • Sound Attenuated Enclosure

Because generators tend to be noisy, we also cater for weather-protective sound attenuated enclosures, which are are zinc plated and made from galvanized steel, to protect both the machinery and those who work with it from noise and vibration.We use anticorrosive paint protection and high gloss polyurethane paint for durability and scuff resistance

Our accoustic canopies are designed to give a sound level of 80 dBA at 1 m. 

Additionally, Scomat provides other sound proofing options which can be suited to your specific needs.

  

  • Fuel Tank

The generator incorporates a day tank which normally caters for 8 hours autonomy as a standard. At Scomat, we provide bulk tanks that allow a longer autonomy, that can go up to even 1 week, to suit your needs.

Amongst our solutions, we also cater for automatic transfer of the fuel from the bulk tank to the day tank of the generator.
  

 

  • Automatic Changeover Panels

 Automatic Changeover Panels can be connected to the generator and the mains so as to immediately start your generator and transfer your load to the generator in case of a power cut. When the mains are back, the system will automatically disconnect the generator and connect the load back to the mains.

We offer a wide variety of automatic changeover panels.

  

  • Control Panels

More than 1 generator can be connected to each other to power your loads. We can provide control panels with synchronising panels incorporated in your generator sets or separate synchronisation panels depending on your needs. 
 

 

 

 

 

 

At Scomat, you'll find highly qualified people; engineers to configure your system and factory-certified technicians to take care of it. We'll size your system, deliver it with every needed accessory, connect it, fuel it, start it, service it and maintain it, and last but not the least...we'll stay with you around the clock.

 

 

Feel free to contact our Dedicated Team on 206-0406.

Definitions

Standby Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).

Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Standard Reference Conditions

Note: Standard reference conditions 25 deg celcius (77 deg F) air inlet temp, 100 m (328ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 amd conforming to BS2869: 1998, Class A2.

 

 

 